The constraint
The counting mechanism needed direction reversal driven purely by current polarity, with angle accuracy and response speed beyond what the standard rotary range offered.
What the customer asked for
- Response within 15 ms
- Life beyond 5,000,000 cycles
- Rotation angle accurate, minimal deviation
What we changed
Rotor and stop materials were selected for the duty; detail-level process control was applied through production; and the design went through several joint iteration rounds with the end customer.
- Careful material selection for the rotor and stop
- Detail-level process control in production
- Multiple iteration rounds together with the end customer
Result
Measured response 10 ms — a third under the requirement. Rotation angle accurate to ±1°, and cycle life verified beyond 5,000,000 operations.
Client identity withheld at their request. Test conditions and measured values are as recorded in the project file; they apply to the configuration described and should not be read as a general specification.