+86 139 2552 1330 [email protected] Dongguan, Guangdong, China
Engineering response within 2 working days
Product family

Push-Pull Solenoids

Pull-in and push-out action from a single coil, with stroke options from 2 mm to 25 mm. The most common choice for latching mechanisms, dispensers and lock bolts.

Push-pull solenoid with return spring

Where this type fits

Pull-in and push-out action from a single coil, with stroke options from 2 mm to 25 mm. The most common choice for latching mechanisms, dispensers and lock bolts.

2–25 mm
Stroke
2–120 N
Force
6/12/24 V
Voltage

How it works

Current through the coil produces a magnetic field that pulls the plunger into the air gap. The useful output is a force that rises steeply as the gap closes — which is why the rated force always belongs to a specific stroke, not to the part in general. Push-Pull designs trade package size against that force profile in a different way from the other families, and the comparison table below reflects that.

Models in this family

ModelDescriptionStroke / orificeForce / pressureVoltage
U0835L-12C13 Rectangular Push-Pull Solenoid up to 8 mm up to 30 N 12 V DC
U1253L/S Compact Open-Frame Push-Pull Solenoid up to 10 mm (curve range) — Custom at order (typ. 12 / 24 V DC)
U0876 Automotive Push-Pull Solenoid 6 mm up to 8 N 12 V DC
U0316L/S Open-frame U0316L/S — — —
U0415L/S Open-frame U0415L/S — — —
U0420L/S Open-frame U0420L/S — — —
U0421L/S Open-frame U0421L/S — — —
U0436L/S Open-frame U0436L/S — — —
U0520L/S Open-frame U0520L/S — — —
U0630L/S Open-frame U0630L/S — — —
U0730L/S Open-frame U0730L/S — — —
U0834L/S Open-frame U0834L/S — — —
U0837L/S Open-frame U0837L/S — — —
U0854L/S Open-frame U0854L/S — — —
U0946L/S Open-frame U0946L/S — — —
U1040L/S Open-frame U1040L/S — — —
U1146L/S Open-frame U1146L/S — — —
U1245L/S Open-frame U1245L/S — — —
U1564L/S Open-frame U1564L/S — — —
U1847L/S Open-frame U1847L/S — — —
U2244L/S Open-frame U2244L/S — — —
U30120L/S Open-frame U30120L/S — — —

What decides the choice

Stroke versus force

Long stroke with high force means a large frame. Fix the stroke first, then see what force is achievable in the space you have.

Duty cycle

Continuous operation needs a coil sized for the temperature rise, not the peak force. Most field failures start here.

Supply and drive

Available voltage, inrush behaviour and whether the drive is a relay, MOSFET or H-bridge all change the coil design.

Environment

Ambient temperature, humidity, dust and vibration determine sealing and insulation class.

What can be customised

  • Coil winding: voltage, resistance, power and insulation class
  • Stroke and force profile for your mechanism
  • Termination: fly leads, PCB pins, connector or terminal block
  • Mounting pattern, plunger end form and return spring
  • Sealing, encapsulation and acoustic damping

Related reading

Have a drawing, a sample, or just a stroke and a force?

Send it over. An engineer reviews every enquiry and replies with a feasible concept, not a brochure.