Battery-powered parcel locker: 8 mm bolt throw on a 150 ms pulse

A locker manufacturer needed a lock that opened reliably on a short pulse and drew no current while closed. The original spring-return design drained the battery in under three weeks.

Locker systemsCustom design
Parcel locker cabinets with solenoid-driven locks, case cover
Actual product and application hardware from the project.

The constraint

Continuous holding current of 180 mA flattened a 4 Ah battery in 19 days.

What we changed

Moved to a bi-stable latching solenoid with a 60 ms drive pulse and a wider bolt throw.

Result

Holding current removed entirely; battery life target extended to 12 months.

Client identity withheld at their request. Test conditions and measured values are as recorded in the project file; they apply to the configuration described and should not be read as a general specification.